Basic specifications for safe use of skid-mounted gas stations and analysis of common faults
Six standardized operations allow skid-mounted gas stations to use electrical equipment safely
During the operation of skid-mounted gas stations, we often avoid using some electrical equipment, which is mainly to prevent sparks from causing unnecessary safety accidents. However, some electrical equipment must be used in the operation of the entire skid-mounted gas station, which is mainly to maintain normal operation. In fact, this is not very important. When using electricity, we only need to follow the following six operating specifications, and safety accidents will stay away from skid-mounted gas stations.
1. Strictly install and use in accordance with the "Technical Specifications for Temporary Electricity Safety at Construction Sites".
2. Be sure to use explosion-proof equipment.
3. Regularly check the power cord for aging, cracking, or too thin wire cores.
4. When laying the line, the connection points must be pressed tightly, and sparks and heating are strictly prohibited.
5. Regardless of the size of the equipment, it is necessary to have a grounding wire.
6. An explosion-proof switch must be installed in the distribution box.
The above six points are the basic specifications for the use of electrical equipment in skid-mounted gas stations. I hope everyone will strictly abide by them. After all, safety is more important than Mount Tai, and it is always more practical to prevent problems before they happen than to be wise after the event.

Analysis of common faults in daily operation of skid-mounted gas stations
Nowadays, many skid-mounted gas stations use double-layer tanks, which can be used to hold fuel and other fuels. After using the double-layer tanks of skid-mounted gas stations for a period of time, faults are inevitable. The following is a detailed sharing of the treatment methods. In case of fire and other accidents: When a fire or other accidents occur when the oil tank is draining water, the relevant operators working on site should immediately stop the draining operation and immediately close the oil tank gate valve; quickly send a fire signal to the entire depot and immediately extract the fire-fighting equipment for repair.
The oil tank drain valve fails and cannot be closed in time. At this time, the mechanic should immediately install the blind plate and report the fault to the oil depot manager. In case of leakage and other accidents, the ongoing draining operation should be stopped immediately, and the alarm signal should be quickly sent to the entire depot and rescue operations should be started immediately.
The double-layer tank drain valve of the skid-mounted gas station fails and cannot be closed. The mechanic should urgently install the blind plate and report to the oil depot manager. If there is an oil leak in the oil tank, the water discharge operation should be stopped immediately, and a signal should be sent to the entire depot quickly and rescue operations should be carried out, and the emergency plan of the oil depot should be implemented in detail.
When a fire occurs when the oil tank of a skid-mounted gas station is discharged, the operator should stop the water discharge operation, close the gate valve, and quickly send a signal to the entire depot. In the process of using the double-layer tank of a skid-mounted gas station, various problems will inevitably arise, and we need to deal with them in time to ensure the normal use of the oil tank.


A brief analysis of the safe operating procedures of skid-mounted gas stations
Safety is the foundation of enterprise operations. In this era of rapid economic and industrial development, safety must be put in front of everything. Safety is the most important thing, and it is definitely not an empty talk and a theory that can withstand historical scrutiny. Today we will analyze the safe operating procedures of skid-mounted gas stations for everyone.
First of all, when maintaining the gasoline filter of a mobile gas station, it is not recommended to burn the filter core with gasoline. When some driver friends maintain the gasoline filter, they like to use gasoline to burn the ceramic filter element to remove impurities on the filter element. Doing so can easily cause fires and affect the service life of the filter element.
Mobile gas stations are located in poorly ventilated areas, and often have tires, batteries, tarpaulins and other equipment placed on the ground. There is also spilled gasoline on the ground. The sparks generated when the fire is struck are likely to ignite the oil molecules in the air. It is strictly forbidden to pour gasoline into the carburetor when the tanker engine is running or when the car is shaking.
The above is the safe operating procedures for using skid-mounted gas stations. I hope it will be helpful to everyone. The methods and steps are summarized through practice. Since there are such steps, there is a reason for their existence. We must strictly follow the installation operating procedures for operation.