Basic methods to avoid static electricity in double-layer oil tanks of skid-mounted gas stations

Release Date: November 05, 2024

We all know that double-layer tanks are the core components of skid-mounted gas stations and the main components for storing oil products, so their safety level is very high, so daily maintenance and upkeep are the most common. In the daily operation process, the biggest threat to the safety of skid-mounted gas stations is still fire. However, in many fire cases, most of them are caused by open flames and static electricity. Today we will introduce to you the basic methods to avoid static electricity in double-layer oil tanks of skid-mounted gas stations.

50kl Mobile Gas Station In Production

When filling oil tanks, tank trucks, and railway tank cars, the oil pipeline must be inserted below the oil surface or close to the bottom of the tank to reduce the impact of the oil products and the friction with the air.

In seasons with particularly dry air and high temperatures, special attention should be paid to checking the grounding equipment, slowing down appropriately, and watering the work site and the static-conducting grounding electrode when necessary.

All oil tanks, pipelines, and loading and unloading equipment used for storing and transferring oil products must have good grounding devices to promptly conduct static electricity into the ground, and the technical condition of the static grounding device should be checked frequently and the grounding resistance should be tested. The grounding resistance of the oil tank in the oil depot should not be greater than 10¦¸ (including static electricity and safety grounding). The grounding electrode of the vertical oil tank is measured according to the circumference of the oil tank, with one group for every 18m, and the grounding electrode of the horizontal oil tank should be no less than two groups.

50kl Mobile Gas Station Ready For Shipment

Static electricity discharge accidents are prone to occur at the beginning of oil transportation and filling, and when the oil is filled to three-quarters to the end of the container. At this time, the flow rate should be controlled within 1m/s.

When the ship is filling oil, the oil outlet of the refueling pipe should be kept in metal contact with the oil inlet of the oil tanker.

It is strictly forbidden to fill light fuel oil into plastic barrels in the oil depot, and it is forbidden to use plastic containers to invert light fuel oil in areas that affect the safety of the oil depot.

50kl Mobile Gas Station Installation Completed

As long as the above points are done well in daily maintenance and care, static electricity can be effectively avoided, thereby increasing the safety index of skid-mounted gas stations to a certain extent. I hope it will be helpful to everyone. Taian Shengding Metal Container Manufacturing Co., Ltd.'s main products include explosion-proof barrier skid-mounted equipment, explosion-proof barrier materials, oil tanks, oil storage tanks, horizontal oil tanks, vertical oil tanks, acid and alkali tanks, water treatment equipment, container heads, boiler auxiliary equipment and other types of metal containers. If you have any needs, please feel free to call us.