Brief analysis of basic operation and troubleshooting of skid-mounted gas station refueling machines

Release Date: September 06, 2024

In the normal operation of skid-mounted gas stations, the maintenance of refueling machines is very important and is also a component with a relatively high maintenance frequency. This is mainly because the gas station not only has a certain impact on the oil in the tank but also has an impact on the refueling accuracy. Today we will explain to you the three basic operations for daily maintenance of skid-mounted gas station refueling machines.

Cleaning the filter:

After the installation and testing of the refueling machine is completed, clean the filter immediately. After the oil machine refuels up to 2000 liters, the filter needs to be cleaned again. In the future, it needs to be cleaned every 6 months. Dirty or clogged filters are manifested as slow oil machine refueling speed, loud noise and vibration. Dirty filters on the oil outlet passage will reduce the oil delivery speed and increase the load of the self-priming pump.

When removing the filter, first find the oil suction filter cover of the pump, unscrew it, and then remove the filter. On the oil separator, the filter cover is on the table. Unscrew the cover, remove the filter, and blow out the debris with compressed air.

20ft Container Skid Mounted Plant 20ft Container Skid Mounted Station Without Refueling Machine

Adjustment of the belt:

If used carefully, the working condition of the belt will be very satisfactory. Loose belts not only reduce the oil delivery rate due to slippage, but also cause excessive wear. A properly tensioned belt can be twisted 180 degrees between the motor and the pulley. Check the belt of the fuel dispenser regularly to confirm that its tension and elasticity are in normal condition.

Protection of the appearance of the fuel dispenser:

Almost all fuel dispensers work outdoors, so the cleanliness of the surface of the fuel dispenser will be affected by weather factors. Therefore, to maintain the beautiful appearance of the fuel dispenser, it must be given reasonable and regular maintenance.

The surface of the fuel dispenser is made of synthetic enamel baked at high temperature, similar to the material on the surface of the car. If it is cleaned regularly with high-grade car detergent and waxed for protection, the brightness of the surface can be extended for several years.

To keep the surface of the fuel dispenser smooth, it must be cleaned frequently. In an environment with corrosive gases, such as coastal areas, the surface of the fuel dispenser needs to be cleaned more frequently. Under normal circumstances, it can be cleaned with detergent and soapy water, and then rinsed with clean water. If hard water is used for cleaning, it must be wiped dry with a soft cloth to prevent water spots from forming. For stains such as grease, oily fingerprints and smoke that cannot be removed by soap and detergent, a stronger detergent must be used (do not use ordinary steel wool, because iron powder will remain on the surface of the gas station and cause corrosion.). When choosing a detergent, be careful that any composite cleaning powder containing abrasives will wear out the surface of the oil machine. When using, apply along the direction of the metal grinding line, do not cross. After cleaning, it is recommended to wax the protection to extend the cleaning time interval.

The above are the three basic operations for daily maintenance of skid-mounted gas station gas stations. I hope that the above description can be of some help to everyone when performing skid-mounted gas station maintenance in the future.

During the operation of the skid-mounted gas station, due to the long-term high-pressure working state, the gas station sometimes has some faults and stops working. At this time, we must immediately find the cause of the car to deal with it to avoid excessive internal pressure in the gas station and cause greater losses. Today we will explain to you the reasons and solutions for the skid-mounted gas station tanker to stop working.

20ft Containerized Skid Mounted Station With Fuel Dispenser

The possible reasons for the tanker not starting are as follows:

1. The tanker circuit is not smooth.

2. The motor, electrical reset and other switches of the tanker are not closed; the connection is not tight.

3. The motor of the tanker stops working due to overheating.

4. The motor is short-circuited or the internal wiring is disconnected.

The simple treatment solution is as follows:

1. Check the fuse or circuit breaker and the main switch;

2. Disassemble the line and check the power supply of the oil machine junction box;

3. Check the reset switch and connect the regulator;

4. Check the connection of the wires through the motor and the electrical reset switch.

5. Touch the motor and check the thermal fuse.

6. Note: Under normal circumstances, the motor feels hotter than the hand can touch. If there is no problem with the above inspection items, the motor may need to be replaced.

The above are the reasons and solutions for the skid-mounted gas station refueling truck to stop working. I hope the above description can be of some help to everyone when using the skid-mounted gas station in the future.