Introduction to New Fire Safety Measures for Skid Mounted Gas Stations
With the popularization of the application of sled mounted gas stations, fire safety measures are gradually improving. While solving the convenience of people's travel, public safety should also be considered. The upgrading of fire safety measures has not stopped for a moment. Today, we will explain the new fire safety measures for sled mounted gas stations.
1. Security interval
The existing or approved sled mounted refueling stations are all barrier explosion-proof types, so this article only focuses on barrier explosion-proof sled mounted refueling devices Explore the fire protection design of Gan. According to the Technical Requirements for Agricultural Automobile Refueling (Gas) Equipment in Yanglou Anti Fire City, when the single tank capacity of the ground fireproof oil tank is greater than 25m2, the total capacity and single tank capacity of the oil tank and compartment should be less than or equal to 50m '. When the single tank capacity of the ground fireproof oil tank is greater than 25m2, a compartment should be set up, and the capacity of the compartment should be less than or equal to 25m.

2. Configuration of fire-fighting facilities and equipment.
The sled mounted refueling device should be equipped with an automatic fire extinguisher, and the starting temperature of the automatic fire extinguisher should not exceed 95C. It should be installed above the working area of the refueling machine. This machine is a dry powder fire extinguisher or foam fire extinguisher P controlled by a fuse valve. It has three starting modes, automatic and manual forced starting, and can be directly injected into the fuel dispenser to achieve the fire extinguishing function. Each fuel dispenser is equipped with at least two automatic fire extinguishers, and a single rated automatic fire extinguisher can be charged with 4kg. Two automatic fire extinguisher decentralized lifting devices The nozzle is facing the fuel dispenser. Here, a more ultra-fine powder fire extinguishing device can be used to replace automatic fire extinguishers, and only one automatic fire extinguisher with a smaller rated capacity and volume can be designed. According to the Technical Specification for Automobile Gas Stations Using Finger Mounted Refueling Devices (SH/T3134-2002) 4.13, every two gas dispensers should be equipped with one set of not less than 8kg portable dry powder fire extinguishers or two sets of 4kg portable dry powder fire extinguishers, one set of not less than 35kg wheeled dry powder fire extinguishers, two sets of fire blankets, one set of fire sandboxes, one set of fine sand storage bags, one set of storage bags, and two sets of storage bags.


3.Protect the equipment.
A protective cofferdam or oil leakage collection pool should be set up around the sled mounted gas station, and the effective capacity of the protective cofferdam or oil leakage collection pool should not be less than the total capacity of the storage tank. The protective cofferdam or oil spill collection tank should be constructed using non combustible solid materials, and the height of the cofferdam should not be less than 500 millimeters. When setting up an oil leakage collection pool at a sled mounted gas station, the foundation surface should be 015-0.2m higher than the ground level to prevent oil accumulation; When setting up a protective cofferdam, the sled mounted gas station can be kept at the level of the ground level. Anti collision facilities should be installed around the sled mounted gas station The distance between the sled mounted refueling device is not more than 1.3m The distance between the pry mounted refueling device shall not be less than 0.8m and not more than 1.2m The effective protection distance for oil tanks and refueling facilities shall not be less than 0.8m and not more than 1.3m.
The above three points are the fire safety measures summarized based on the safety hazards that have occurred in the current application process of the sled mounted gas station. We hope everyone can strictly follow them.
Written by
TAIAN SHENGDING METAL CONTAINER MANUFACTURING CO., LTD.
Editor Wang
www.self-bunded-tank.com
WhatsApp : +86 152 5486 3111
Email :shengdingtank@126.com
- WhatsApp
- E-MailE-Mail:shengdingtank@126.com
- WeChatWeChat:15254863111